Publication Beamlines Strategic Pillar
de A. Melo, Lis G.; Botton, G.A.; Hitchcock, Adam P. (2015). Quantification of the critical dose for radiation damage to perfluorosulfonic acid membranes using soft X-ray microscopy. Microscopy and Microanalysis 21(S3) , 2443-2444. 10.1017/s1431927615012994. SM Materials
Duffy, Alan; Fodje, Michel; Berg, Russ; Grochulski, Pawel (2007). Canadian Macromolecular Crystallography Facility (CMCF) 08ID-1 status update. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 582(1) , 82-83. 10.1016/j.nima.2007.08.066. CMCF-ID Materials
Ge, Nan; Chevalier, Stéphane; Hinebaugh, James; George, Michael Gerald; Lee, Jongmin et al. (2016). Roles of Photon Scattering in Synchrotron X-ray Radiography of In Operando Visualizations of the Polymer Electrolyte Membrane Fuel Cell. ECS Transactions 75(14) , 261-274. 10.1149/07514.0261ecst. BMIT-BM Materials
George, Michael G; Liu, Hang; Banerjee, Rupak; Ge, Nan; Shrestha, Pranay et al. (2016). Accelerated Degradation of Polymer Electrolyte Membrane Fuel Cell Gas Diffusion Layers: Mass Transport Resistance and Liquid Water Accumulation at Limiting Current Density with in operando Synchrotron X-ray Radiography. ECS Transactions 75(14) , 89-100. 10.1149/07514.0089ecst. BMIT-BM Materials
Grochulski; P.; Fodje; M.N.; Delbaere et al. (2007). CMCF 08ID-1 Beamline at the Canadian Light Source. In Acta Crystallogr.. International Union of Crystallography. , 245 https://doi.org/10.1107/S0108767307094469. CMCF-ID Materials
Hinebaugh, James; Lee, Jongmin; Bazylak, Aimy (2013). Visualizing Liquid Water Evolution in a PEM Fuel Cell Using Synchrotron Radiography. ECS Transactions 50(2) , 343-352. 10.1149/05002.0343ecst. BMIT-BM Materials
Hitchcock, A. P.; Wu, J.; Lee, V.; Appathurai, N.; Tyliszczak, T. et al. (2016). Progress in Soft X-ray Microscopy Characterization of PEM Fuel Cell Catalyst Layers. Microscopy and Microanalysis 22(S3) , 1290-1291. 10.1017/s1431927616007297. SM Materials
Johns, PC; Bewer, BE; Chapman, LD (2009). Poster - Wed Eve-12: Initial Experiments in Monoenergetic X-Ray Scatter Imaging at the BioMedical Imaging and Therapy facility of the Canadian Light Source. Medical Physics 36(9Part2) , 4306-4306. 10.1118/1.3244116. BMIT-BM Materials
Johns; P.C.; Warkentin; B. (2010). Canadian Light Source now accepting Imaging and Therapy Users. In 2010 Canadian Organization of Medical Physicists. . , 46-47 https://www.comp-ocpm.ca/download.php?id=360. BMIT-BM Materials
Landheer; Karl; Johns; Paul C. (2012). Coherent x-ray scatter projection imaging using an array of monoenergetic pencil beams. In Proceeding SPIE. . , 83581O 10.1117/12.918666. BMIT-BM Materials
Lee; J.; Hinebaugh; J.; Bazylak et al. (2012). The impact of an MPL on water management of an operating PEMFC using synchrotron X-ray radiography. In Proceedings of ASME. . , 205-212 10.1115/FuelCell2012-91454. BMIT-BM Materials
Lee, Jongmin; Banerjee, Rupak; Ge, Nan; Chevalier, Stéphane; George, Michael Gerald et al. (2016). Performance Benefits of Multiwall Carbon Nanotubes in the Polymer Electrolyte Membrane Fuel Cell Gas Diffusion Layer. ECS Transactions 75(14) , 237-244. 10.1149/07514.0237ecst. BMIT-BM Materials
Lee, Jongmin; Yip, Ronnie; Antonacci, Patrick; Ge, Nan; Kotaka, Toshikazu et al. (2014). Impact of MPL Thickness on Water Management of PEMFC by Synchrotron X-ray Radiography. ECS Transactions 61(12) , 69-81. 10.1149/06112.0069ecst. BMIT-BM Materials
Liu; Dong; Maxwell; Dylan; Matias et al. (2012). Web applications for experimental control at CLS. In 2012 IEEE 8th International Conference on E-Science. . , 6404470 10.1109/escience.2012.6404470. BMIT Materials
London; Mike; Cameron; Shauna M; Donald et al. (2014). Waterflooding Experiments with X-ray CT Imaging. In Society of Petroleum Engineers. . , SPE-170147-MS 10.2118/170147-ms. BMIT-BM Materials