Landheer; Karl; Johns; Paul C. (2012). Coherent x-ray scatter projection imaging using an array of monoenergetic pencil beams. In Proceeding SPIE. . , 83581O 10.1117/12.918666. |
BMIT-BM |
Conference Proceeding |
Materials |
Lee; J.; Hinebaugh; J.; Bazylak et al. (2012). The impact of an MPL on water management of an operating PEMFC using synchrotron X-ray radiography. In Proceedings of ASME. . , 205-212 10.1115/FuelCell2012-91454. |
BMIT-BM |
Conference Proceeding |
Materials |
Lee, Jongmin; Yip, Ronnie; Antonacci, Patrick; Ge, Nan; Kotaka, Toshikazu et al. (2014). Impact of MPL Thickness on Water Management of PEMFC by Synchrotron X-ray Radiography. ECS Transactions 61(12) , 69-81. 10.1149/06112.0069ecst. |
BMIT-BM |
Conference Proceeding |
Materials |
London; Mike; Cameron; Shauna M; Donald et al. (2014). Waterflooding Experiments with X-ray CT Imaging. In Society of Petroleum Engineers. . , SPE-170147-MS 10.2118/170147-ms. |
BMIT-BM |
Conference Proceeding |
Materials |
Miller, C Denise; Wysokinski, Tomasz W; Belev, George; Chapman, L Dean (2013). Human factors design for the BMIT biomedical beamlines. Journal of Physics: Conference Series 425(2) , 022005. 10.1088/1742-6596/425/2/022005. |
BMIT-BM, BMIT-ID |
Conference Proceeding |
Materials |
Rahman, K M Mostafijur; Szpunar, Jerzy; Belev, George (2013). In Situ 3D Synchrotron Imaging of Failure Processes in Engineering Materials. Journal of Physics: Conference Series 425(13) , 132004. 10.1088/1742-6596/425/13/132004. |
BMIT-BM |
Conference Proceeding |
Materials |
Rhoades, Glendon; Belev, George; Rosenberg, Alan; Chapman, Dean (2013). A Novel Analyzer Control System for Diffraction Enhanced Imaging. Journal of Physics: Conference Series 425(2) , 022003. 10.1088/1742-6596/425/2/022003. |
BMIT-BM |
Conference Proceeding |
Materials |
Yip, Ronnie; Lee, Jongmin; Hinebaugh, James; Fishman, Zachary; Ellis, Jonathan S. et al. (2014). (Plenary) Advanced Visualization Tools to Investigate PEM Fuel Cell Materials. ECS Transactions 64(3) , 27-45. 10.1149/06403.0027ecst. |
BMIT-BM |
Conference Proceeding |
Materials |
Basnayaka, Upekha; Chapman, Dean; Adams, Gregg; Wysokinski, Tomasz; Belev, George et al. (2014). Diffraction-enhanced Synchrotron Imaging of Bovine Ovaries Ex Vivo. Journal of Medical Imaging and Radiation Sciences 45(3) , 307-315. 10.1016/j.jmir.2014.01.004. |
BMIT-BM |
Peer-Reviewed Article |
Health |
Britz, Hayley M.; Carter, Yasmin; Jokihaara, Jarkko; Leppänen, Olli V.; Järvinen, Teppo L.N. et al. (2012). Prolonged unloading in growing rats reduces cortical osteocyte lacunar density and volume in the distal tibia. Bone 51(5) , 913-919. 10.1016/j.bone.2012.08.112. |
BMIT-BM |
Peer-Reviewed Article |
Health |
Cooper, David M. L.; Bewer, Brian; Wiebe, Sheldon; Belev, George; Wysokinski, Tomasz et al. (2011). Preliminary Bone Imaging on 05B1-1 Beamline at the Canadian Light Source: Exploration of Diffraction Enhanced Imaging. Synchrotron Radiation News 24(2) , 13-18. 10.1080/08940886.2011.567163. |
BMIT-BM |
Peer-Reviewed Article |
Health |
Cooper, David M.L.; Bewer, Brian; Wiebe, Sheldon; Wysokinski, Tomasz W.; Chapman, Dean et al. (2011). Diffraction Enhanced X-ray Imaging of the Distal Radius: A Novel Approach for Visualization of Trabecular Bone Architecture. Canadian Association of Radiologists Journal 62(4) , 251-255. 10.1016/j.carj.2010.04.015. |
BMIT-BM |
Peer-Reviewed Article |
Health |
Cooper, D M L; Chapman, L D; Carter, Y; Wu, Y; Panahifar, A et al. (2012). Three dimensional mapping of strontium in bone by dual energy K-edge subtraction imaging. Physics in Medicine and Biology 57(18) , 5777-5786. 10.1088/0031-9155/57/18/5777. |
BMIT-BM |
Peer-Reviewed Article |
Health |
Luan, Xiaojie; Campanucci, Verónica A.; Nair, Manoj; Yilmaz, Orhan; Belev, George et al. (2014). Pseudomonas aeruginosa
triggers CFTR-mediated airway surface liquid secretion in swine trachea. Proceedings of the National Academy of Sciences of the United States of America 111(35) , 12930-12935. 10.1073/pnas.1406414111. |
BMIT-BM |
Peer-Reviewed Article |
Health |
Midgley, S M (2013). Feasibility study for DEXA using synchrotron CT at 20–35 keV. Physics in Medicine and Biology 58(4) , 1185-1205. 10.1088/0031-9155/58/4/1185. |
BMIT-BM |
Peer-Reviewed Article |
Health |