Landheer; Karl; Johns; Paul C. (2012). Coherent x-ray scatter projection imaging using an array of monoenergetic pencil beams. In Proceeding SPIE. . , 83581O 10.1117/12.918666. |
BMIT-BM |
Conference Proceeding |
Materials |
Bolibruch; N.I.; Vogt; J.M.; Igarashi et al. (2011). Photodiode Calibration using an Electrical Substitution Radiometer in the Hard X-Ray Region. In Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators. Joint Accelerator Conferences Website (JACoW). , 500-502 https://accelconf.web.cern.ch/accelconf/DIPAC2011/papers/tupd83.pdf. |
BMIT-BM, HXMA |
Conference Proceeding |
Materials |
Lee; J.; Hinebaugh; J.; Bazylak et al. (2012). The impact of an MPL on water management of an operating PEMFC using synchrotron X-ray radiography. In Proceedings of ASME. . , 205-212 10.1115/FuelCell2012-91454. |
BMIT-BM |
Conference Proceeding |
Materials |
Anderson; D.; Warkentin; B.; Siegbahn et al. (2010). Dosimetry for Microbeam Radiation Therapy at the Canadian Light Source. In Forty-Sixth Annual Meeting of the Canadian organization of Medical Physicists and the Canadian College of Physicists in Medicine. . , 3904 https://doi.org/10.1118/1.3476189. |
BMIT-BM |
Conference Proceeding |
Materials |
Johns; P.C.; Warkentin; B. (2010). Canadian Light Source now accepting Imaging and Therapy Users. In 2010 Canadian Organization of Medical Physicists. . , 46-47 https://www.comp-ocpm.ca/download.php?id=360. |
BMIT-BM |
Conference Proceeding |
Materials |
Johns, PC; Bewer, BE; Chapman, LD (2009). Poster - Wed Eve-12: Initial Experiments in Monoenergetic X-Ray Scatter Imaging at the BioMedical Imaging and Therapy facility of the Canadian Light Source. Medical Physics 36(9Part2) , 4306-4306. 10.1118/1.3244116. |
BMIT-BM |
Conference Proceeding |
Materials |
Rahman, K M Mostafijur; Szpunar, Jerzy; Belev, George (2013). In Situ 3D Synchrotron Imaging of Failure Processes in Engineering Materials. Journal of Physics: Conference Series 425(13) , 132004. 10.1088/1742-6596/425/13/132004. |
BMIT-BM |
Conference Proceeding |
Materials |
Boire, S; Zhu, Y; Belev, G; Samadi, N; Szyszkowski, W et al. (2013). A novel beam width doubling double crystal monochromator -some preliminary findings. Journal of Physics: Conference Series 425(5) , 052010. 10.1088/1742-6596/425/5/052010. |
BMIT-BM |
Conference Proceeding |
Materials |
Miller, C Denise; Wysokinski, Tomasz W; Belev, George; Chapman, L Dean (2013). Human factors design for the BMIT biomedical beamlines. Journal of Physics: Conference Series 425(2) , 022005. 10.1088/1742-6596/425/2/022005. |
BMIT-BM, BMIT-ID |
Conference Proceeding |
Materials |
Rhoades, Glendon; Belev, George; Rosenberg, Alan; Chapman, Dean (2013). A Novel Analyzer Control System for Diffraction Enhanced Imaging. Journal of Physics: Conference Series 425(2) , 022003. 10.1088/1742-6596/425/2/022003. |
BMIT-BM |
Conference Proceeding |
Materials |
Cooper, David M. L.; Bewer, Brian; Wiebe, Sheldon; Belev, George; Wysokinski, Tomasz et al. (2011). Preliminary Bone Imaging on 05B1-1 Beamline at the Canadian Light Source: Exploration of Diffraction Enhanced Imaging. Synchrotron Radiation News 24(2) , 13-18. 10.1080/08940886.2011.567163. |
BMIT-BM |
Peer-Reviewed Article |
Health |
Wysokinski, Tomasz W.; Chapman, Dean; Adams, Gregg; Renier, Michel; Suortti, Pekka et al. (2007). Beamlines of the biomedical imaging and therapy facility at the Canadian light source—Part 1. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 582(1) , 73-76. 10.1016/j.nima.2007.08.087. |
BMIT-BM, BMIT-ID |
Peer-Reviewed Article |
Health |
Olkowski, A. A.; Laarveld, B.; Wojnarowicz, C.; Chirino-Trejo, M.; Chapman, D. et al. (2011). Biochemical and physiological weaknesses associated with the pathogenesis of femoral bone degeneration in broiler chickens. Avian Pathology 40(6) , 639-650. 10.1080/03079457.2011.626017. |
BMIT-BM, MID-IR |
Peer-Reviewed Article |
Health |
Britz, Hayley M.; Carter, Yasmin; Jokihaara, Jarkko; Leppänen, Olli V.; Järvinen, Teppo L.N. et al. (2012). Prolonged unloading in growing rats reduces cortical osteocyte lacunar density and volume in the distal tibia. Bone 51(5) , 913-919. 10.1016/j.bone.2012.08.112. |
BMIT-BM |
Peer-Reviewed Article |
Health |
Cooper, D M L; Chapman, L D; Carter, Y; Wu, Y; Panahifar, A et al. (2012). Three dimensional mapping of strontium in bone by dual energy K-edge subtraction imaging. Physics in Medicine and Biology 57(18) , 5777-5786. 10.1088/0031-9155/57/18/5777. |
BMIT-BM |
Peer-Reviewed Article |
Health |