Ge, Nan; Chevalier, Stéphane; Hinebaugh, James; George, Michael Gerald; Lee, Jongmin et al. (2016). Roles of Photon Scattering in Synchrotron X-ray Radiography of In Operando Visualizations of the Polymer Electrolyte Membrane Fuel Cell. ECS Transactions 75(14) , 261-274. 10.1149/07514.0261ecst. |
BMIT-BM |
Conference Proceeding |
Materials |
Chevalier; S.; Banerjee; R.; Lee et al. (2016). In situ liquid water visualization in polymer electrolyte membrane fuel cells with high resolution synchrotron x-ray radiography. In AIP Conference Proceedings. . , 050006-1 – 050006-4 10.1063/1.4952926. |
BMIT-BM |
Conference Proceeding |
Materials |
Banerjee; Rupak; Han; Chuzhang; Ge et al. (2017). Synchrotron X-Ray Investigation of Membrane Water Distribution in Polymer Electrolyte Membrane Fuel Cell Applications. In ASME 2017 15th International Conference on Nanochannels, Microchannels, and Minichannels. . 10.1115/icnmm2017-5556. |
BMIT-BM |
Conference Proceeding |
Materials |
Banerjee, Rupak; Ge, Nan; Lee, Jongmin; George, Michael Gerald; Liu, Hang et al. (2016). Determining the Impact of Dynamic Load Conditions on Interfacial Liquid Water Accumulation in Polymer Electrolyte Membrane Fuel Cell Gas Diffusion Layers Using Synchrotron X-Ray Radiography. ECS Transactions 75(14) , 251-259. 10.1149/07514.0251ecst. |
BMIT-BM |
Conference Proceeding |
Materials |
Aulakh, Gurpreet K.; Kuebler, Wolfgang M.; Singh, Baljit; Chapman, Dean (2017). Visualization of Rib and Diaphragm Motion in an Anaesthetized Mouse by Live Animal Synchrotron Imaging. IEEE. 10.1109/nssmic.2017.8533101. |
BMIT-BM |
Conference Proceeding |
Health |
Anderson, Danielle; Siegbahn, Albert; Fallone, Gino; Warkentin, Brad (2016). Poster - 15: Air kerma rate measurements using a cylindrical free-air ionization chamber on the 05B1-1 beamline at the Canadian Light Source. Medical Physics 43(8Part2) , 4939. 10.1118/1.4961789. |
BMIT-BM |
Conference Proceeding |
Materials |
Wysokinski; Tomasz W.; Chapman; L. Dean; Miller et al. (2016). 25+2 poles, 4.3 T wiggler at BMIT - 7 years operational experience. In AIP Conference Proceedings. . , 020026-1 – 020026-4 10.1063/1.4952805. |
BMIT-ID |
Conference Proceeding |
Materials |
Tomasz Wysokinski; Denise Miller; Robert Blyth; Pawel Grochulski (2018). Life Science Programs at the Canadian Light Source: Overview Of The Bio-medical Studies At BMIT. . https://proceedings.cmbes.ca/index.php/proceedings/article/view/607/600. |
BMIT-BM, BMIT-ID |
Conference Proceeding |
Health |
Panahifar, A.; Chapman, D.; Cooper, D.M. (2018). Synchrotron x-ray imaging applications in osteoarthritis. Osteoarthritis and Cartilage 26, S472-S473. 10.1016/j.joca.2018.02.890. |
BMIT-BM, BMIT-ID |
Conference Proceeding |
Agriculture |
Mark Webb; George Belev; Melanie Gibbons; Denise Miller; Tomasz Wysokinski et al. (2017). Live Animal Imaging Program at Bio-Medical Imaging and Therapy Facility at the Canadian Light Source. . http://inspirehep.net/record/1649849/. |
BMIT-BM, BMIT-ID |
Conference Proceeding |
Health |
Luo; Peng; Li; Sheng; Knorr et al. (2018). Underlying Mechanisms of Tight Reservoir Wettability and Its Alteration. In Proceedings - SPE Symposium on Improved Oil Recovery. . , 1-15 10.2118/190214-ms. |
BMIT-ID |
Conference Proceeding |
Materials |
Linda Lin; Tomasz Wysokinski (2017). CLSI BMIT's Super-Conducting Wiggler Cryogenic Safety Improvements. . http://inspirehep.net/record/1649811/. |
BMIT-ID |
Conference Proceeding |
Materials |
Karhula, S.S.; Finnilä, M.A.; Cooper, D.M.; Miller, D.; Valkealahti, M. et al. (2018). 3D analysis of local grey-level variance from micro-CT images is associated with osteocyte cellularity in human osteoarthritic subchondral bone. Osteoarthritis and Cartilage 26, S90. 10.1016/j.joca.2018.02.195. |
BMIT-ID |
Conference Proceeding |
Health |
Hedayat; Assem; Wu; Pengyu (2018). EndoCal 10 Obturation Voids in Root Canal and Isthmus of a Human Premolar: A Synchrotron micro-CT Imaging Study. In BIOIMAGING 2018. SciTePress. , 43-49 10.5220/0006582900430049. |
BMIT-ID |
Conference Proceeding |
Health |
Hedayat, Assem; Belev, George; Zhu, Ning; Bond, Toby; Cooper, David et al. (2018). Investigating the Presence of Mercury under a Dental Restoration Using Synchrotron K-Edge Subtraction Imaging. Microscopy and Microanalysis 24(S2) , 364-365. 10.1017/s1431927618014101. |
BMIT-ID |
Conference Proceeding |
Health |