Publication Beamlines Strategic Pillar
Panahifar, A.; Cooper, D.M.; Doschak, M.R. (2015). Synchrotron-based 3-D functional micro-CT imaging of dynamic strontium label to localize pathological bone adaptations in post-traumatic osteoarthritis. Osteoarthritis and Cartilage 23, A78-A79. 10.1016/j.joca.2015.02.156. BMIT-BM Health
Banerjee; Rupak; Han; Chuzhang; Ge et al. (2017). Synchrotron X-Ray Investigation of Membrane Water Distribution in Polymer Electrolyte Membrane Fuel Cell Applications. In ASME 2017 15th International Conference on Nanochannels, Microchannels, and Minichannels. . 10.1115/icnmm2017-5556. BMIT-BM Materials
Liu; Dong; Maxwell; Dylan; Matias et al. (2012). Web applications for experimental control at CLS. In 2012 IEEE 8th International Conference on E-Science. . , 6404470 10.1109/escience.2012.6404470. BMIT Materials
Hedayat, Assem; Belev, George; Zhu, Ning; Bond, Toby; Cooper, David et al. (2018). Investigating the Presence of Mercury under a Dental Restoration Using Synchrotron K-Edge Subtraction Imaging. Microscopy and Microanalysis 24(S2) , 364-365. 10.1017/s1431927618014101. BMIT-ID Health
Finnilä, M.A.; Karhula, S.S.; Cooper, D.M.; Belev, G.; Nieminen, H.J. et al. (2017). Synchrotron Micro-computed Tomography Reveals Increased Osteocyte Volume in Subchondral Bone with Osteoarthritis Severity. Osteoarthritis and Cartilage 25, S299-S300. 10.1016/j.joca.2017.02.505. BMIT-ID Health
Karhula, S.S.; Finnilä, M.A.; Cooper, D.M.; Miller, D.; Valkealahti, M. et al. (2018). 3D analysis of local grey-level variance from micro-CT images is associated with osteocyte cellularity in human osteoarthritic subchondral bone. Osteoarthritis and Cartilage 26, S90. 10.1016/j.joca.2018.02.195. BMIT-ID Health
Panahifar, A.; Chapman, D.; Cooper, D.M. (2018). Synchrotron x-ray imaging applications in osteoarthritis. Osteoarthritis and Cartilage 26, S472-S473. 10.1016/j.joca.2018.02.890. BMIT-BM, BMIT-ID Agriculture
Finnilä, M.A.; Karhula, S.S.; Cooper, D.M.; Valkealahti, M.; Joukainen, A. et al. (2018). 3D osteocyte morphology and volume of chondrocyte clusters are modulated with osteoarthritis severity. Osteoarthritis and Cartilage 26, S70. 10.1016/j.joca.2018.02.149. BMIT-ID Health
Chevalier; S.; Banerjee; R.; Lee et al. (2016). In situ liquid water visualization in polymer electrolyte membrane fuel cells with high resolution synchrotron x-ray radiography. In AIP Conference Proceedings. . , 050006-1 – 050006-4 10.1063/1.4952926. BMIT-BM Materials
Samadi; Nazanin; Martinson; Mercedes; Bassey et al. (2016). An energy dispersive bent Laue monochromator for K-edge subtraction imaging. In AIP Conference Proceedings. . , 040004-1 – 040004-4 10.1063/1.4952876. BMIT-BM Materials
Dydula; Christopher; Belev; George; Johns et al. (2017). Accelerated x-ray scatter projection imaging using multiple continuously moving pencil beams. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE. . , 101324J 10.1117/12.2253720. BMIT-ID Materials
Wysokinski; Tomasz W.; Chapman; L. Dean; Miller et al. (2016). 25+2 poles, 4.3 T wiggler at BMIT - 7 years operational experience. In AIP Conference Proceedings. . , 020026-1 – 020026-4 10.1063/1.4952805. BMIT-ID Materials
Bree; Michael; Miller; Denise; Kerr et al. (2016). Alignment and position visualization methods for the biomedical imaging and therapy (BMIT) MRT lift. In AIP Conference Proceeding. . , 030023-1 – 030023-4 10.1063/1.4952846. BMIT-ID Materials
Belev, G.; Miller, D.; Samadi, N.; Webb, M. A.; Wysokinski, T. W. et al. (2015). 4 Years of X-ray Imaging at 05B1-1 Beamline at BMIT. IFMBE Proceedings , 162-165. 10.1007/978-3-319-19387-8_39. BMIT-BM, BMIT-ID Materials
Bassey, B.; Mercedes, M.; Samadi, N.; Belev, G.; Karanfil, C. et al. (2015). Multiple Energy Synchrotron Biomedical Imaging System- Preliminary Results. IFMBE Proceedings , 248-251. 10.1007/978-3-319-19387-8_60. BMIT-BM Materials